Electroacoustic Analysis System

Electroacoustic Analysis System

The CRY6125 Electroacoustic Tester is a comprehensive device designed to assess the performance of various electroacoustic components while resisting environmental noise. It measures a wide range of indicators, including sensitivity (SPL), impedance, total harmonic distortion (THD), resonance frequency (F0), quality factor (Q), equivalent volume, and audio power amplifier characteristics. Suitable for testing microphones, electret microphones, transmitters, receivers, earphones, headset microphone assemblies, communication helmets, speakers, buzzers, and more, the CRY6125 offers measurement frequencies ranging from 10 Hz to 65 kHz.

No items found.

Technical Specifications

No items found.
No items found.
Please choose a topic.
Other
Optional accessories
Optional accessories
CRY series mouth and ear simulatorsCRY series 1/2'' microphone and preamplifier
Power supply
Power supply
50Hz,220V ± 10%
Operating environment
Operating environment
+10℃ ~ +300℃,RH ≤ 80%
Whole instrument error
Whole instrument error
≤ ±1dB
Feature
Feature
Data and curves can be printed on paper
Mouth simulator
Range
Range
84~104dB
Frequency Response
Frequency Response
≤ ±2dB(0.2~40kHz)
Distortion measurement
Frequencies
Frequencies
300Hz、500Hz、600Hz、1kHz、1.2kHz、2.4kHz、3kHz
Impedance measurement
Frequency range
Frequency range
0.02~20kHz
Measurement Range
Measurement Range
-30dB ~ +20dB(0dB=1kHz,rated impedance: 1 - 1000 Ω)
Amplitude measurement
Frequency range
Frequency range
0.02 - 20kHz; frequency response ≤ ±0.5 dB (based on 1 kHz)0.01 - 40kHz; frequency response ≤ ±2 dB (based on 1 kHz)
Amplitude range
Amplitude range
Electric signal measurement: -70 dB to +10 dB (0 dB = 1 V)Acoustic signal measurement: 60 dB to 140 dB (94 dB = 1 Pa)Measurement error: ≤ ±0.5 dB
Sweep signal
Frequency range (0.01 - 40 kHz)
Frequency range (0.01 - 40 kHz)
0.02 - 20 kHz; frequency response ≤ ±0.2 dB (based on 1 kHz)0.01 - 40kHz; frequency response ≤ ±0.5 dB (based on 1 kHz)Frequency error < 0.01%
Amplitude range
Amplitude range
50 - 5000 mV; error ≤ ±0.2 dB; distortion < 1%
Frequency band mode
Frequency band mode
0.1~10kHz、0.2~20kHz、0.01~40kHz、10~65kHz
Octave mode
Octave mode
1/3、1/6、1/12、1/24、1/48、1/96、1/192(optional)
Output impedance
Output impedance
0、1Ω、150Ω、300Ω、450Ω、10kΩ、or32Ω

Download

Get in touch

Are you seeking more information about CRYSOUND's solutions or need a demo? Contact us via the form bleow and one of our sales or support engineers will connect with you.
No items found.
Addition Plug-in
Microphone Array
Intrinsic Safe
Test Contents
Number of Channels
IEC 61672-1:2013 Class
Feature
Structure
Operation
Size of Microphone
Polarization
Application
Contact Testing