Field Type
Pressure-field
field-type-cry3404
Noominal Sensitivity
0.56mV/Pa, -65±3dB re 1V/Pa
noominal-sensitivity-cry3404
Frequency Response
10Hz to 20kHz±2dB
frequency-response-cry3404
Polarization Voltage
0V
polarization-voltage-cry3404
Dynamic Range(re.20uPa)
59dBA to 175dB
dynamic-range-re-20upa-cry3404
Operating Temperature
-30 to +70℃ (-22 to +158℉)
operating-temperature-cry3404
Temperature Stability
-0.002dB/℃(-10 to +50℃) -0.001dB/℉(+14 to +122℉)
temperature-stability-cry3404
Static Pressure Stability
-0.01dB/kPa
static-pressure-stability-cry3404
Operating Humidity Range
0 to 90%RH no condensation
operating-humidity-range-cry3404
Humidity Stability
< 0.1dB (0 to 90%RH no condensation)
humidity-stability-cry3404
Pressure Equalization Vent
Side vented
pressure-equalization-vent-cry3404
IEC 61094-4 Type
WS3P
iec-61094-4-type-cry3404
Height with Grid
10.5mm (0.413")
height-with-grid-3404
Diameter with Grid
7mm (0.276")
diameter-with-grid-3404