Field Type
Pressure-field
field-type-cry3402-s02
Noominal Sensitivity
1.6mV/Pa, -56±3dB re 1V/Pa
noominal-sensitivity-cry3402-s02
Frequency Response
4Hz to 70kHz±2dB
frequency-response-cry3402-s02
Polarization Voltage
0V
polarization-voltage-cry3402-s02
Dynamic Range(re.20uPa)
45dBA to 161dB
dynamic-range-re-20upa--cry3402-s02
Operating Temperature
-20 to +60℃ (-4 to +140℉)
operating-temperature-cry3402-s02
Temperature Stability
0.010dB/℃(-10 to +50℃) 0.006dB/℉(+14 to +122℉)
temperature-stability-cry3402-s02
Static Pressure Stability
-0.01dB/kPa
static-pressure-stability-cry3402-s02
Operating Humidity Range
0 to 90%RH no condensation
operating-humidity-range-cry3402-s02
Humidity Stability
< 0.1dB (0 to 90%RH no condensation)
humidity-stability-cry3402-s02
Pressure Equalization Vent
Side vented
pressure-equalization-vent-cry3402-s02
IEC 61094-4 Type
WS3P
iec-61094-4-type-cry3402-s02
Output Impedance
< 20Ω
output-impedance-cry3402-s02
Maximum Output Voltage
> 5.0Vrms
maximum-output-voltage-cry3402-s02
Current Source
IEPE (2mA to 10mA)
current-source-cry3402-s02
Typical Operating Current
4mA
typical-operating-current-cry3402-s02
Interface Type
Microdot
interface-type-cry3402-s02
Height with Grid
62.5mm (2.461")
height-with-grid-3402-s02
Diameter with Grid
7mm (0.276")
diameter-with-grid-3402-s02