![CRY3101-S01 Measurement microphone set](https://www.crysound.com/en/upload/2024/05/23/171644834680532dmxs.png)
![CRY3101-S01 Measurement microphone set](https://www.crysound.com/en/upload/2024/05/23/171644834680532dmxs.png)
CRY3101-S01 Measurement microphone set
The CRY3101-S01 is a free-field prepolarized microphone and preamplifier set specifically designed for sensitive acoustic testing in low-noise environments, such as anechoic chambers and quiet rooms. It is also widely applicable in various fields that require precise acoustic testing, research in acoustical design, and calibration testing of audio equipment, including speakers and headphones.
![Standards](https://www.crysound.com/en/upload/2024/05/27/171677777321526fo9l.png)
Standards
IEC 61094 4:1995 Measurement microphones - Part 4
Frequency response
The CRY3101-S01 is a free-field prepolarized microphone and preamplifier set specifically designed for sensitive acoustic testing in low-noise environments, such as anechoic chambers and quiet rooms. It is also widely applicable in various fields that require precise acoustic testing, research in acoustical design, and calibration testing of audio equipment, including speakers and headphones.
![Frequency response](https://www.crysound.com/en/upload/2024/05/27/171677772510292ezlh.png)
![Frequency response](https://www.crysound.com/en/upload/2024/05/27/171677772510292ezlh.png)
Frequency response
The CRY3101-S01 is a free-field prepolarized microphone and preamplifier set specifically designed for sensitive acoustic testing in low-noise environments, such as anechoic chambers and quiet rooms. It is also widely applicable in various fields that require precise acoustic testing, research in acoustical design, and calibration testing of audio equipment, including speakers and headphones.
Technical specification |
---|
Field Type | Free-field |
Nominal Sensitivity | 50mV/Pa, -26 ±1.5dB re 1V/Pa |
Frequency Response | 4Hz to 16kHz ±2dB |
Polarization Voltage | 0V |
Dynamic Range(re.20uPa) | 12dBA to 132dB |
Operating Temperature | -20 to +60℃ (-4 to +140℉) |
Temperature Stability | 0.015dB/℃ (-10 to +50℃) 0.008dB/℉ (14 to 122℉) |
Static Pressure Stability | -0.01dB/kPa |
Operating Humidity Range | 0 to 90%RH no condensation |
Humidity Stability | < 0.1dB (0 to 90%RH no condensation) |
Pressure Equalization Vent | Rear vented |
IEC 61094-4 Type | WS1F |
Output Impedance | <20Ω |
Maximum Output Voltage | >5.0Vrms |
Current Source | IEPE (2mA to 10mA) |
Typical Operating Current | 4mA |
Interface Type | BNC |
-