CRY3101-S01 Measurement microphone set
CRY3101-S01 Measurement microphone set
  • CRY3101-S01 Measurement microphone set

CRY3101-S01 Measurement microphone set

The CRY3101-S01 is a free-field prepolarized microphone and preamplifier set specifically designed for sensitive acoustic testing in low-noise environments, such as anechoic chambers and quiet rooms. It is also widely applicable in various fields that require precise acoustic testing, research in acoustical design, and calibration testing of audio equipment, including speakers and headphones.

Features
Standards

Standards

IEC 61094 4:1995 Measurement microphones - Part 4

Frequency response

The CRY3101-S01 is a free-field prepolarized microphone and preamplifier set specifically designed for sensitive acoustic testing in low-noise environments, such as anechoic chambers and quiet rooms. It is also widely applicable in various fields that require precise acoustic testing, research in acoustical design, and calibration testing of audio equipment, including speakers and headphones.

Frequency response
Frequency response

Frequency response

The CRY3101-S01 is a free-field prepolarized microphone and preamplifier set specifically designed for sensitive acoustic testing in low-noise environments, such as anechoic chambers and quiet rooms. It is also widely applicable in various fields that require precise acoustic testing, research in acoustical design, and calibration testing of audio equipment, including speakers and headphones.

Technical specification
Technical specification
Field TypeFree-field
Nominal Sensitivity50mV/Pa, -26 ±1.5dB re 1V/Pa
Frequency Response4Hz to 16kHz ±2dB
Polarization Voltage0V
Dynamic Range(re.20uPa)12dBA to 132dB
Operating Temperature-20 to +60℃ (-4 to +140℉)
Temperature Stability0.015dB/℃ (-10 to +50℃)
0.008dB/℉  (14 to 122℉)
Static Pressure Stability-0.01dB/kPa
Operating Humidity Range0 to 90%RH no condensation
Humidity Stability< 0.1dB (0 to 90%RH no condensation)
Pressure Equalization VentRear vented
IEC 61094-4 TypeWS1F
Output Impedance<20Ω
Maximum Output Voltage>5.0Vrms
Current SourceIEPE (2mA to 10mA)
Typical Operating Current4mA
Interface TypeBNC
More products
CRY3102-S01 Measurement microphone set
CRY3102-S01 Measurement microphone set
More
After-sales services
  • 20 years industry experience

  • 24 hours Technical Support

  • Professional engineers on line response

  • 2 hours response
    Solution within 2 work days

  • All life Costs Maintenance

Activity Registration
If you need to ask the price of CRYSOUND acoustic imager, reserve the free test for a limited time.Please input information and requirements according to the form, and we will arrange engineers to contact you as soon as possible.
*
*
*
*
*
Please select your requirements (pops)*
Consulting the price
Appointment Demo